About OJO | Search | Ahead of print | Current Issue | Archives | Author Instructions | Reviewer Guidelines | Online submissionLogin 
Oman Journal of Ophthalmology Oman Journal of Ophthalmology
  Editorial Board | Subscribe | Advertise | Contact
https://www.omanophthalmicsociety.org/ Users Online: 258  Wide layoutNarrow layoutFull screen layout Home Print this page  Email this page Small font size Default font size Increase font size
ORIGINAL ARTICLE
Year : 2018  |  Volume : 11  |  Issue : 2  |  Page : 144-149

Influence of total intraocular lens diameter on efficacy and safety for in the bag cataract surgery


Department of Ophthalmology, Ludwig Maximilians University of Munich, Munich, Germany

Correspondence Address:
Efstathios Vounotrypidis
Department of Ophthalmology, Ludwig Maximilians University of Munich, Mathildenstr 8, D-80336 Munich
Germany
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ojo.OJO_143_2017

Rights and Permissions

> CONTEXT: Intraocular lenses with variable total diameter are supposed to fit better in the capsular bag and lead to fewer complications. AIMS: This study aims to investigate the efficacy and the safety of an intraocular lens model with variable total diameter. SETTINGS AND DESIGN: Prospective randomized intraindividual study. SUBJECTS AND METHODS: Thirty-two eyes of sixteen patients with bilateral age-related cataract received standard cataract surgery with implantation of an intraocular lens with a standard diameter in one eye (Quatrix®, Group A) and with a variable total diameter in the fellow eye (Quatrix Evolutive®, Group B). Primary study endpoints included evaluation of refraction stability and posterior capsule opacification (PCO) over a follow-up period of 6 months. STATISTICAL ANALYSIS USED: SPSS (Version 19.0) was used for statistical analysis. RESULTS: Uncorrected and corrected distant visual acuity after 6 months were 0.24 and 0.1 LogMAR in Group A and 0.23 and 0.09 LogMAR in Group B, respectively. The objective and manifest spherical equivalent (OSE, MSE) 6 months postoperatively were + 0.65 D and + 0.62 D in Group A compared to + 0.33 D and + 0.33 D in Group B respectively (P = 0.665 for OSE, P = 0.208 for MSE). PCO-index increased statistically significant in both groups (P = 0.004 in Group A, P = 0.046 in Group B), but the difference of PCO-index between both groups was not statistically significant (P = 0.569). CONCLUSIONS: An intraocular lens with a variable total diameter shows good visual outcomes and safety performance as well as same outcomes concerning postoperative refractive stability and development of PCO compared to an intraocular lens with standard total diameter.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed2464    
    Printed90    
    Emailed0    
    PDF Downloaded58    
    Comments [Add]    

Recommend this journal