Efficacy of three different formulations of brimonidine for control of intraocular pressure in primary open-angle glaucoma: A 6-week randomized trial


1 Department of Ophthalmology, Sri Guru Ram Das Institute of Medical Sciences and Research, Amritsar, Punjab, India
2 Department of Ophthalmology, Government Medical College, Patiala, Punjab, India

Correspondence Address:
Anubha Bhatti
H. No. 3024, Sector - 37D, Chandigarh
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ojo.OJO_98_2016

Rights and Permissions

BACKGROUND: To compare the intraocular pressure (IOP)-lowering efficacy and safety of brimonidine (0.2%), brimonidine purite (0.15%), and brimonidine purite (0.1%) in patients of primary open-angle glaucoma (POAG). MATERIALS AND METHODS: Sixty patients of POAG with IOP >21 mmHg were enrolled into this study for 6-week duration. The patients were randomly divided into three groups with 20 patients in each group. Group A instilled brimonidine 0.2%, Group B instilled brimonidine purite 0.15%, and Group C instilled brimonidine purite 0.1% twice daily. IOP was recorded by applanation tonometry at baseline and subsequently at 2, 4, and 6 weeks at 9:00–10:00 am during each visit around 30 min after instillation of eye drops. RESULTS: Mean IOP reduction in Group A was from 25.55 ± 2.01 to 19.85 ± 2.05 mmHg at the end of study, thus resulting in fall of 5.70 mmHg (22.30%), in Group B, it decreased from 25.65 ± 2.41 to 19.55 ± 2.43 mmHg, thus resulting in fall of 6.10 mmHg (23.78%), and in Group C, it decreased from 25.80 ± 2.26 mmHg to 19.85 ± 2.16 mmHg, thus resulting in fall of 6.35 mmHg (24.61%). There was no statistically significant difference in IOP-lowering efficacy of study drugs. Conjunctival hyperemia, foreign body sensation, dry eye, and papillary reaction were the important side effects seen with study drugs. Brimonidine 0.2% caused more side effects than brimonidine purite 0.15% and brimonidine purite 0.1%. CONCLUSION: All the three formulations of brimonidine produced statistically equal lowering of IOP in patients of POAG with reduced systemic and ocular adverse reactions with brimonidine purite 0.15% and 0.1%.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed3338    
    Printed106    
    Emailed0    
    PDF Downloaded67    
    Comments [Add]    

Recommend this journal