About OJO | Search | Ahead of print | Current Issue | Archives | Author Instructions | Reviewer Guidelines | Online submissionLogin 
Oman Journal of Ophthalmology Oman Journal of Ophthalmology
  Editorial Board | Subscribe | Advertise | Contact
https://www.omanophthalmicsociety.org/ Users Online: 700  Wide layoutNarrow layoutFull screen layout Home Print this page  Email this page Small font size Default font size Increase font size


 
ORIGINAL ARTICLE
Year : 2010  |  Volume : 3  |  Issue : 2  |  Page : 66-69 Table of Contents   

Indirect evaluation of corneal apoptosis in contact lens wearers by estimation of nitric oxide and antioxidant enzymes in tears


1 Department of Ophthalmology, Institute of Medical Sciences, Banaras Hindu University, Varanasi, India
2 Department of Biophysics, Institute of Medical Sciences, Banaras Hindu University, Varanasi, India
3 Department of Pharmacology, Institute of Medical Sciences, Banaras Hindu University, Varanasi, India

Date of Web Publication9-Jun-2010

Correspondence Address:
Amitabh Dash
E-13, Kalkaji, New Delhi-110 019
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0974-620X.64229

Rights and Permissions
   Abstract 

Background : Contact lens induced trauma to the corneal epithelium results in increased release of inflammatory mediators. The keratocyte apoptosis is directly related to epithelial injury and has been correlated with increased production of nitric oxide. Potent antioxidant enzymes protect cells from oxidative damage by inactivating reactive oxygen species and thus inhibiting apoptosis. This study aims at determination of total nitric oxide and antioxidant enzymes in tears which will be an indirect criteria for assessing apoptosis.
Materials and Methods : Nitric oxide and antioxidant enzymes were estimated in tears of 25 soft contact lens wearers and compared with 25 age and sex matched controls.
Results : Statistically significant increase of nitric oxide (P<0.001), superoxide dismutase (P<0.001) and glutathione peroxidase (P<0.001) levels was seen in tears of contact lens wearers as compared to controls. There was also statistically significant increase in the levels of antioxidant enzymes, superoxide dismutase (P<0.05) and glutathione peroxidase (P<0.01), with increase in the total duration of contact lens wear in years.
Conclusions : Increase in the level of nitric oxide and antioxidant enzymes in tears of contact lens wearers suggested that contact lens wear suppresses the process of apoptosis. However, it was also postulated that the increased levels of nitric oxide balances the anti-apoptotic activities of increased levels of antioxidant enzymes by its pro-apoptotic activity leading to protective outcomes in contact lens wearers.

Keywords: Apoptosis, contact lens, glutathione peroxidase, nitric oxide, superoxide dismutase


How to cite this article:
Bhatia R P, Dhawan S, Khanna H D, Dash A. Indirect evaluation of corneal apoptosis in contact lens wearers by estimation of nitric oxide and antioxidant enzymes in tears. Oman J Ophthalmol 2010;3:66-9

How to cite this URL:
Bhatia R P, Dhawan S, Khanna H D, Dash A. Indirect evaluation of corneal apoptosis in contact lens wearers by estimation of nitric oxide and antioxidant enzymes in tears. Oman J Ophthalmol [serial online] 2010 [cited 2023 Mar 31];3:66-9. Available from: https://www.ojoonline.org/text.asp?2010/3/2/66/64229


   Introduction Top


Apoptosis is a process of deliberate life relinquishment by a cell in a multicellular organism. It is one of the main types of programmed cell death, [1] and involves an orchestrated series of biochemical events leading to a characteristic cell morphology and death. In contrast to necrosis, which is a form of traumatic cell death that results from acute cellular injury, apoptosis is carried out in an orderly process that generally confers advantages during an organism's life cycle. The process of apoptosis in controlled by a diverse range of cell signals which may originate either extracellularly or intracellularly. [1] These signals may positively or negatively induce apoptosis.

Mechanical stimulation of corneal surface, due to the physical presence of contact lens, may result in increased release of cytokines, growth factors and other inflammatory mediators. [2] Jalbert and Stapleton [3] and Efron et al.[4] showed that keratocyte density in the human cornea decreases during contact lens wear. The contact lens induced keratocyte apoptosis observed by these investigators was attributed to three possible etiologies: hypoxia, cytokine-mediated effects, and mechanically induced effects. Cytokine mediated cytoxicity has been correlated with upregulation of inducible nitric oxide synthase and elevated denovo production of nitric oxide. [5] Nitric oxide has been demonstrated to be involved in the regulation of apoptosis. [6]

Cellular oxidants, called reactive oxygen species (ROS) induce oxidative damage in cells and are essential mediators of apoptosis. [7] Potent antioxidant enzymes such as superoxide dismutase (SOD) and glutathione peroxidase (GSH) protect cells from oxidative damage by inactivating ROS and thus inhibit apoptosis. [8]

This study aims at determination of nitric oxide (NO) and antioxidant enzymes in tears.

  • Tear fluid specimen will be taken and subjected to ELISA estimation for determination of levels of NO.
  • Tear fluid specimen will be analyzed by spectrophotometric methods for activities of enzymes SOD and GSH.
  • Values of NO and antioxidant enzymes in tears will be correlated with the total duration of contact lens wear and daily contact lens wear time.



   Materials and Methods Top


This study was done at Bhuwalika Eye Hospital, Department of Ophthalmology in conjunction with Department of Biophysics, Institute of Medical Sciences, Banaras Hindu University, Varanasi. The study was reviewed and approved by the Institutional Ethics Committee.

A total of 25 contact lens wearers were included. Out of 25 cases, 20 patients were females and 5 were males and their age ranged from 20 to 30 years. Cases were divided according to total duration of contact lens wear in years and average daily contact lens wear time in hours [Table 1]. All the contact lens wearers were myopic.

Methods

Tears were collected from controls and contact lens wearers in sitting posture by placing capillary tube at the lateral canthus, without corneal anaesthesia, taking care to ensure that no contact was made with the lid margin and corneal surface. Tears were sucked by capillary action into the tube. Patient was asked to look straight to avoid any trauma. Tears were then immediately transferred to a microtube for the estimation of NO, SOD, GSH.

Estimation of nitric oxide in tears

The quantitative determination of NO was done using the Assay Designs' NO assay kit (Assay Designs Inc., USA). The kit involved the enzymatic conversion of nitrate to nitrite, by the enzyme nitrate reductase, followed by the colorimetric detection of nitrite as a colored azo dye product of the Griess reaction that absorbs visible light at 540 nm.

Estimation of antioxidant enzymes in tears

The activities of two antioxidant enzymes SOD and GSH in tears were analyzed by spectrophotometric methods.


   Results Top


The mean NO level in contact lens wearers was 127.35 ± 69.58 μmol/L while the mean NO level in controls was 80.90 ± 31.78 μmol/L. The increase in mean NO level in contact lens wearers as compared to controls was statistically significant p<0.001; [Table 2].

Mean NO level in contact lens wearers did not vary significantly with duration of contact lens wear in years or average daily contact lens wear time in hours p>0.001; [Table 3].

The mean SOD level in contact lens wearers was 189.43 ± 113.31 U/ml while the mean SOD level in controls was 80.90 ± 31.78 U/mL. The increase in mean SOD level in contact lens wearers as compared to controls was statistically significant (p<0.001) [Table 2].

On comparison of mean SOD level with total duration of contact lens wear in years, the result was statistically significant (p<0.05). Mean SOD level did not vary significantly with average daily contact lens wear time in hours (p>0.001) [Table 4].

The mean GSH level in contact lens wearers was 3771.43 ± 2831.79 U/L while the mean GSH level in control was 501.35 ± 383.36 U/L. The increase in GSH level in contact lens wearers as compared to controls was statistically significant (p<0.001) [Table 2].

On comparison of mean GSH level with total duration of contact lens wear in years, the result was statistically significant (p0<0.01). Mean GSH level did not vary significantly with average daily contact lens wear time in hours (p>0.001) [Table 5].


   Discussion Top


Programmed cell death (apoptosis) is the controlled cell death that occurs with minimal collateral damage to surrounding cells or tissue during development, homeostasis and wound healing. [9],[10] A cell that undergoes apoptosis, in contrast to necrosis, involutes with little accompanying inflammation and without the release of degradative components that would inflict collateral damage to surrounding tissues. [11] In response to epithelial injury, anterior keratocytes undergo apoptosis. Keratocyte apoptosis is the first change noted after procedures in which the epithelium is injured and might be an initiator of the subsequent wound healing cascade. [12] Responses to mechanical induced injury such as due to contact lens and corneal tissue organization occurs through initiation of keratocyte apotosis. [13]

Contact lens induced trauma to the epithelium results in increased release of cytokines, growth factors and other inflammatory mediators. [2] This cytokines mediated cytotoxicity has been linked with upregulation of inducible NO synthase and elevated denovo production of NO. [5] NO has been shown to be able to induce apoptosis and also to protect from apoptosis in different cell types. [6]

We report the results of an indirect study of apoptosis in contact lens wearers done by estimation of nitric oxide and antioxidant enzymes in tears in contact lens wearers and compared with controls. A statistically significant increase in mean NO level in contact lens wearers as compared to controls was observed. The NO levels did not vary significantly with total duration of lens wear in years and average daily lens wear time in hours. Additionally, there was statistically significant increase in mean SOD level in contact lens wearers as compared to controls. The SOD levels varied significantly with total duration of lens wear in years but did not vary significantly with average daily lens wear time. A statistically significant increase in mean GSH level in contact lens wearers as compared to controls was also detected. The GSH levels also varied significantly with total duration of lens wear in years but did not vary significantly with average daily lens wear time.

Previous studies have shown that ocular tissues and fluids contain high molecular weight antioxidants such as glutathione peroxidase and superoxide dismutase that play a key role in protecting against oxidative damage. [14] Under physiological conditions, these antioxidant enzymes protect the cornea against oxidative stress [15],[16],[17],[18] increase in ROS concentration by depletion of antioxidants has been shown to enhance apoptosis. On the contrary, excessive antioxidants decrease ROS level and inhibit apoptosis. [7]

We hypothesize that increased levels of nitric oxide in tears of contact lens wearers possibly supports the apoptotic process. However, a significant increase in the level of antioxidant enzyme activities in tears in contact lens wearers suggests that there is a suppression of the process of apoptosis in contact lens wearers. The former has to nullify the antioxidant enzymes induced anti-apoptotic activity in a favorable way, thereby protecting the corneal and conjuctival cells by apoptosis which is a homeostatic mechanism. However further studies are required to explain fully the effect of changes in the levels of NO and antioxidant emzymes in the tear films of contact lens wearers on corneal apoptosis.

 
   References Top

1.Fadeel B, Orrenius S. Apoptosis: a basic biological phenomenon with wide-ranging implications in human disease. J Intern Med 2005;258:479-517.  Back to cited text no. 1      
2.Kallinikos P, Efron N. On the etiology of keratocyte loss during contact lens wear. Invest Ophthalmol Vis Sci 2004;45:3011-20.  Back to cited text no. 2      
3.Jalbert I, Stapleton F. Effect of lens wear on corneal stroma: Preliminary findings. Aust N Z J Ophthalmol 1999;27:211-3.  Back to cited text no. 3      
4.Efron N, Perez-Gomez I, Morgan PB. Confocal microscopic observations of stromal keratocytes during extended contact lens wear. Clin Exp Optom 2002;85:156-60.  Back to cited text no. 4      
5.Sagoo P, Chan G, Larkin DF, George AJ. Inflammatory cytokines induce apoptosis of corneal endothelium through nitric oxide. Invest Ophthalmol Vis Sci 2004;45:3964-73.  Back to cited text no. 5      
6.Brόne B, von Knethen A, Sandau KB. Nitric oxide (NO): an effector of apoptosis. Cell Death Differ 1999;6:969-75.  Back to cited text no. 6      
7.Salganik RI. The benefits and hazards of antioxidants: controlling apoptosis and other protective mechanisms in cancer patients and the human population. J Am Coll Nutr 2001;20:464S-72S.  Back to cited text no. 7      
8.Bilgihan K, Bilgihan A, Adiguzel U, Sezer C, Yis O, Akyol G, et al. Keratocyte apoptosis and corneal antioxidant enzyme activities after refractive corneal surgery. Eye (Lond) 2002;16:63-8.  Back to cited text no. 8      
9.Wyllie AH, Kerr JF, Currie AR. Cell death: the significance of apoptosis. Int Rev Cytol 1980;68:251-306.  Back to cited text no. 9      
10.Arends MJ, Wyllie AH. Apoptosis: mechanisms and roles in pathology. Int Rev Exp Pathol 1991;32:223-54.  Back to cited text no. 10      
11.Helena MC, Baerveldt F, Kim WJ, Wilson SE. Keratocyte apoptosis after corneal surgery. Invest Ophthalmol Vis Sci 1998;39:276-83.  Back to cited text no. 11      
12.Wilson SE. Role of apoptosis in wound healing in the cornea. Cornea 2000;19:7-13.   Back to cited text no. 12      
13.Wilson SE, He YG, Weng J, Li Q, McDowall AW, Vital M, Chwang EL. Epithelial injury induces keratocyte apoptosis: hypothesized role for the interleukin-1 system in the modulation of corneal tissue organization and wound healing. Exp Eye Res 1996;62:325-7.  Back to cited text no. 13      
14.Cejkovα J, Stνpek S, Crkovskα J, Ardan T, Plαtenνk J, Cejka C, et al. UV Rays, the prooxidant / antioxidant imbalance in the cornea and oxidative eye damage. Physiol Res 1004;53:1-10.  Back to cited text no. 14      
15.Bhuyan KC, Bhuyan DK. Regulation of hydrogen peroxide in eye humors. Effect of 3-amino-1H-1,2,4-triazole on catalase and glutathione peroxidase of rabbit eye. Biochim Biophys Acta 1977;497:641-51.  Back to cited text no. 15      
16.Bhuyan KC, Bhuyan DK. Superoxide dismutase of the eye: relative functions of superoxide dismutase and catalase in protecting the ocular lens from oxidative damage. Biochim Biophys Acta 1978;542:28-38.  Back to cited text no. 16      
17.Behndig A, Svensson B, Marklund SL, Karlsson K. Superoxide dismutase isoenzymes in the human eye. Invest Ophthalmol Vis Sci 1998;39:471-5.  Back to cited text no. 17      
18.Cejkovα J, Stνpek S, Crkovskα J, Ardan T. Changes of superoxide dismutase, catalase and glutathione peroxidase in the corneal epithelium after UVB rays. Histochemical and biochemical study. Histol Histopathol 2000;15:1043-50.  Back to cited text no. 18      



 
 
    Tables

  [Table 1], [Table 2], [Table 3], [Table 4], [Table 5]


This article has been cited by
1 Current status and future perspective of sonodynamic therapy for cancer
Atsushi Sofuni, Takao Itoi
Journal of Medical Ultrasonics. 2022;
[Pubmed] | [DOI]
2 The role of nitric oxide in ocular surface physiology and pathophysiology
Shyam Sunder Tummanapalli, Rajesh Kuppusamy, Jia Hao Yeo, Naresh Kumar, Elizabeth J. New, Mark D.P. Willcox
The Ocular Surface. 2021; 21: 37
[Pubmed] | [DOI]



 

Top
 
  Search
 
  
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
    Abstract
    Introduction
    Materials and Me...
    Results
    Discussion
    References
    Article Tables

 Article Access Statistics
    Viewed4831    
    Printed245    
    Emailed0    
    PDF Downloaded546    
    Comments [Add]    
    Cited by others 2    

Recommend this journal