About OJO | Search | Ahead of print | Current Issue | Archives | Author Instructions | Reviewer Guidelines | Online submissionLogin 
Oman Journal of Ophthalmology Oman Journal of Ophthalmology
  Editorial Board | Subscribe | Advertise | Contact
https://www.omanophthalmicsociety.org/ Users Online: 396  Wide layoutNarrow layoutFull screen layout Home Print this page  Email this page Small font size Default font size Increase font size
ORIGINAL ARTICLE
Year : 2009  |  Volume : 2  |  Issue : 1  |  Page : 27-32

Long-term variability in short-wavelength automated perimetry compared to standard perimetry in glaucoma patients and normal subjects


Department of Ophthalmology, Himalayan Institute of Medical Sciences, Jolly Grant, Dehradun, Uttarakhand, India

Correspondence Address:
Chintan Malhotra
Department of Ophthalmology, Himalayan Institute of Medical Sciences, Jolly Grant, Dehradun
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0974-620X.48419

Rights and Permissions

Aims: To compare long-term variability (LTV) in short-wavelength automated perimetry (SWAP) with that of standard white-on-white (W-W) perimetry, in primary open angle glaucoma (POAG) patients and normal subjects and to determine its clinical significance. Patients and Methods: The sample comprised 30 patients of stable POAG (group 1) and 20 age-matched normal controls (group2) who performed both SWAP and W-W perimetry thrice at monthly intervals. Long-term variability at each location in the visual field was calculated as the standard deviation of three threshold decibel values taken from the three visual fields performed. Mean LTV was then calculated for the entire field for each subgroup and compared. Results: Mean LTV in SWAP and W-W perimetry in glaucoma patients was 3.01 0.74 dB and 2.73 1.07dB respectively. In normal subjects mean LTV of SWAP and W-W perimetry was 2.69 0.91 db and 1.97 1.34 dB respectively. Intra group analysis revealed that mean LTV of SWAP was greater compared to W-W perimetry in normal subjects and glaucoma patients. In the latter, the difference did not reach statistical significance. Inter group analysis showed that mean LTV in both SWAP and W-W perimetry was greater in glaucoma patients than in normal subjects. Factors other than POAG that could influence LTV, including progression of cataract and change in pupil size due to use of pilocarpine were excluded. Mean examination time for SWAP per sitting was 7.65% longer than that for W-W perimetry. Conclusions: Higher mean LTV of SWAP as compared to W-W perimetry needs to be taken into consideration when evaluating serial visual fields for change. Use of rapid threshold algorithms e.g. SITA (Swedish interactive test algorithm) SWAP should be encouraged as these will reduce the patient fatigue and increase the reliability of the test.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed2448    
    Printed186    
    Emailed0    
    PDF Downloaded452    
    Comments [Add]    

Recommend this journal